Browse all practice questions for the North Carolina Public Utilities License Practice Test. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

Ace the North Carolina Public Utilities License 2026 – Power Up Your Career Path! course image
All questions

These questions are part of the practice quiz. Start practicing

  • What is a guy in the context of pole setting?
  • Which type of fuse links must fit into a 7/17-inch diameter hole?
  • What is the maximum change in direction permitted in any plane lengths of straight, rigid conduit without the use of bends?
  • What should the tension in bottom conductors be in relation to the top conductors?
  • Which component is critical in the controlling of electrical flow in a rectifying device?
  • Which type of roof would be the easiest to maintain on a utility pole?
  • What typically limits the capacity of conductors in a transmission circuit?
  • Transmission structures are typically set in place using what equipment?
  • What voltage defines the primary function of high-voltage transmission lines?
  • What does a head guy refer to?
  • Why is clearance important for service-drop wires in pedestrian areas?
  • What is the normal inside vertical height of a two-way manhole?
  • If 120/7620 x 10/1 equals what primary current?
  • What does underground cable shielding prevent?
  • What is the typical line voltage range mentioned for electrical systems?
  • What causes radio interference on high-voltage DC transmission lines?
  • What is the minimum depth for grounding rods to ensure they are in perpetually moist earth?
  • Where can underground cable circuits originating in pad-mounted switchgear be grounded?
  • What characteristic does a clean, dry polypropylene rope possess compared to other types?
  • What equipment can be used with the head of a hydraulically operated tool for working on energized lines?
  • What is the clearance required for voltages between 345,000 to 362,000 volts?
  • What aspects does the Unisagwatch calibration take into account?
  • What is the most common method used to set poles?
  • What is the purpose of roofing poles?
  • What is the function of cable cutters in the splicing process?
  • How deep should the top of a conduit system be located below the top of the rails of a street railway?
  • What device indicates that a high-voltage line is de-energized?
  • In high-voltage systems, what is a common voltage range needed for transferring electricity over long distances?
  • What is the recommended method for pulling poles?
  • What is the primary function of a distribution transformer?
  • What is the role of safety hats in electrical work?
  • What role do coupling capacitors serve in electrical transmission?
  • What type of polarity is standard for all single-phase distribution transformers?
  • What shape is the core of the most commonly used transformer design?
  • What must be done to a line before it can be worked on?
  • Which side of the pole is referred to as the concave side?
  • What key features does a distribution transformer include?
  • What type of maintenance is essential for ensuring the proper functioning of shield wires?
  • During a Lamp Test for Polarity on a Three-Wire Service, which wire causes the lamp to burn?
  • What is the purpose of brushing the aluminum conductor surface before applying an inhibitor-type compound?
  • Under what circumstances should the boom of the line truck not be used?
  • What is a key advantage of properly roofing utility poles?
  • Which of the following is a common practice when handling cables in a manhole?
  • What is the standard wire size often used for ground connections?
  • What type of test should rubber gloves be given daily by linemen or cablemen?
  • In which scenario are head guys typically used?
  • What is the importance of high-frequency voltages in coupling capacitors?
  • In a shell-type transformer, where are the coils placed?
  • What component is used in oil switches to open circuits automatically during overloads?
  • What is the minimum clearance for service-drop wires in areas restricted to pedestrian traffic?
  • What additional action can be taken if resistance is too high when using a grounding rod?
  • The main purpose of adding capacitors to a circuit is to:
  • Which of the following is NOT mentioned as a common conductor covering?
  • What is the minimum size of the ground wire used?
  • In electrical systems, sagging of conductors is typically addressed during which phase?
  • What device provides continuous indication of ground resistance?
  • What size conductor is typically required for underground services to new homes?
  • How can the tension in a conductor be measured?
  • What is a thyristor semiconductor primarily used for?
  • What is vital for ensuring precision during the calibration process of the Unisagwatch?
  • During tension stringing, what element is critical to maintaining conductor elevation?
  • What voltage is typically used to test the insulated stick portion of hot-line tools?
  • What does the term "vault" refer to in the context of manholes?
  • What must not happen to the conductor while removing cable insulation?
  • Under what condition is a flat roof type considered adequate for poles?
  • Which of the following describes the purpose of conducting phasing out operations in utility work?
  • Which type of rope is considered an insulator?
  • Where does the lineman make the last connection when installing protective grounds?
  • Why are the core and coils of a large capacity transformer typically placed in an oil-filled tank?
  • What is the typical range of generation values (voltage) for electrical power?
  • What does the Unisagwatch device provide direct readings of?
  • What purpose does spacing serve between cables in a manhole?
  • What is the primary purpose of a guy wire?
  • What should ties for pin-type insulators achieve?
  • What is the purpose of tension stringing in electrical installations?
  • Where should a distribution transformer be primarily installed?
  • What is an essential factor for ensuring personal safety in electrical work?
  • At what location is voltage raised to transmission levels?
  • What is the approximate insulating value of a standard safety hat?
  • What is commonly used as a conductor covering?
  • What is the function of a light-duty strain carrier (rocker-arm type)?
  • At what point do sagging operations begin during the installation process?
  • In terms of utility structure placement, what should one consider regarding the surface conditions?
  • Different ratings of transformers are known to have what?
  • How deep should the top of a conduit system be below the top of the rails of a railroad?
  • What is the line voltage and conductor size for typical overhead AC three-phase transmission lines?
  • What is an important safety consideration when using hot-line tools?
  • Why is aluminum conductor often preferred in electrical applications?
  • How is a neutral conductor in a power system typically characterized?
  • What is the minimum clearance required for voltages between 46,100 to 72,500 volts?
  • What is the primary use of wire tongs in electrical work?
  • What is the consequence of not clipping in conductors promptly after sagging?
  • How often should bonding be provided between supply conductors and communication shields?
  • What does limiting radio interference help to achieve?
  • What feature do capacitors for use on electrical lines have?
  • What is the role of a dynamometer in the process described?
  • At what voltage are hot-line tools typically factory tested?
  • What is the key purpose of conducting an air test on rubber gloves?
  • When should conductors and shield wires be clipped in after sagging is completed?
  • What is the function of grounding a line before working on it?
  • What is expected of the ties used for tying conductors to ensure safety?
  • What does the term "Frequency" refer to in electrical terms?
  • Under what conditions must all high-voltage electric transmission and distribution circuits be installed underground?
  • What happens to the power factor when voltage and current are out of phase?
  • Which roofing types are commonly used when roofing poles?
  • Which of the following is a situation where piking might be used?
  • How is the operation of circuit switches initiated in DC circuits?
  • If a grounding rod shows resistance above 25 ohms, what is the recommended action?
  • What factors limit the lengths of sag sections in overhead conductors?
  • In underground distribution, what is necessary for protecting cable components?
  • How should poles be oriented when placed next to poles supporting long spans?
  • What type of manholes are used for the protection of transformer and network protector equipment?
  • How are new safety helmets tested for insulation?
  • Why is the proper choice of a connector considered important?
  • What is the purpose of the cable insulation shielding?
  • When should a cable exposed at a fault location be handled?
  • What devices can transformers be equipped with for operational efficiency?
  • What does it mean to ground a circuit or apparatus?
  • What is the required burial depth for supply conductors or cables operating at 601 to 22,000 volts?
  • Where are splices normally completed when underground ducts are used?
  • What is the frequency of the AC power generated in the United States and Canada?
  • What is a common safety practice before using electrical gloves?
  • Why is it important to coat the brushed aluminum conductor with an inhibitor-type compound?
  • What is the purpose of ground wire molding?
  • A transformer’s efficiency is most adversely affected by:
  • Why is it important to identify the correct cable before beginning work?
  • What does AC Live-line Work Minimum Approach Distance refer to?
  • What voltage threshold do new helmets achieve according to safety standards?
  • What should be done if the resistance of a grounding rod is not well below 25 ohms?
  • At what height should service supports be mounted?
  • What is one characteristic of the face of a pole?
  • What is the primary purpose of training cables on the manhole wall?
  • What should the end goal be when completing a splice?
  • What does cable insulation shielding protect against?
  • What should be the state of capacitors after 5 minutes of disconnection?
  • What is the minimum separation required between supply and communications facilities in joint-use manholes and vaults for voltages between 15,001 to 50,000 volts?
  • What typically varies depending on the height and length of the wall in manholes?
  • Where are transmission substations primarily located?
  • What is defined as the transmission level voltage?
  • Why is it important to check rubber gloves daily?
  • Under what condition is the Power Factor considered to be unity?
  • How far from the suspension of dead-end points should all splices in transmission-line conductors be made?
  • What is the primary method for setting H-Frames?
  • What is the function of the trip coil in an oil switch?
  • How can the measuring of sag be conducted for small sag situations?
  • What is one method to improve a low power factor of below .80?
  • In electrical safety, what does the term 'maximum use voltage' refer to?
  • What type of hazard do rubber gloves help protect against?
  • What is the purpose of using various taps in the windings of distribution transformers?
  • What device is used to easily measure the resistance of ground lines in service?
  • Which of the following best describes the purpose of thermal conditions in transmission circuits?
  • Where do grounded static wires for transmission lines originate?
  • What is the purpose of an elastomeric damper?
  • What is the piking method in pole setting?
  • The primary purpose of a fuse link is to protect against what condition in electrical circuits?
  • What is the typical residential voltage configuration in North Carolina?
  • What is the potential risk of improperly nicking a conductor during installation?
  • When is phasing out necessary in electrical work?
  • What feature is designed to protect a distribution transformer from lightning?
  • How long should you wait before working on a disconnected capacitor for safety?
  • What application has seen the use of two-pole H-type structures?
  • What determines the capacity of a distribution transformer?
  • When pulling bundled conductors, how are they typically managed?
  • What is the maximum use voltage for Class 2 gloves?
  • What purpose does a cable spear serve in electrical work?
  • What is the approximate weight of the head of a hydraulically operated tool used for compression splicing?
  • Under what conditions is the Unisagwatch particularly suitable for use?
  • What component of safety gear is tested for their insulating capability against stated voltage?
  • What should be checked during a visual inspection of rubber gloves?
  • What is the function of slant cut and gable roof types on poles?
  • What is one of the primary risks associated with live-line work?
  • What does a shield wire do in electrical installations?
  • What is the risk of having insufficient setting depth for a utility pole?
  • What is the recommended spacing between cable racks adjacent to a proposed cable splice?
  • What is the term for surface damage identifiable by black deposits on a conductor?
  • What is a primary factor that contributes to the stability of flexible towers?
  • How deep should a 40-foot pole be set according to the setting depth rule?
  • What is a common issue with measuring sag during installations with unusually small sags?
  • What device is used to check if each line conductor is de-energized before installing protective grounds?
  • How does a lineman or cableman identify the cable to be worked on at the pad-mounted transformer?
  • How much straight cable should extend beyond each end of the splice?
  • What is the maximum length of a sag section typically allowed?
  • In three-phase transformers, what does ensuring that the phase sequence is not changed help with?
  • What is one purpose of determining the phase sequence in a three-phase system?
  • What material is not typically used as a conductor covering in electrical applications?
  • What aspect of a transformer is directly related to its design temperature?
  • Most electric energy generation occurs at voltages lower than what threshold?
  • What is the minimum required depth for a ground rod installation?
  • What is a recommended practice when closing a fuse cutout?
  • Which of the following is true regarding service-drop wire polarity?
  • What is often included in the features of a protective link for a distribution transformer?
  • Why are Power Thyristors being integrated into some step voltage regulators?
  • What is the rule for determining the setting depth of poles?
  • Conductors can be connected for parallel operation when what condition is met?
  • What is the recommended pole hole diameter for adequate tamping equipment space?
  • What happens if a grounding rod is not driven deep enough?
  • At what location can underground cable conductors terminating in pad-mounted transformers be grounded?
  • What is the minimum grade required for conduit runs to ensure drainage into the manhole?
  • How is Power Factor calculated?
  • What is the role of power transformers in transmission substations?
  • What is the purpose of a compression sleeve connector in electrical systems?
  • How many suspension units are typically required for a string of conductors?
  • What voltage level can a properly maintained Class 2 glove handle?
  • What should be taken into consideration when pulling a pole?
  • Which of the following describes the core's function in a transformer?
Subscribe

Get the latest from Examzify

You can unsubscribe at any time. Read our privacy policy